VCFRONT_a509 — Vcright eFuse Load Shed

Full alert identifier: VCFRONT_a509_vcrightEFuseLoadShed

Alert description

Electrical current flowing through the right vehicle controller (VCRIGHT) eFuse has equaled or exceeded 100A. The VCRIGHT eFuse circuit may open (trip) if low voltage (LV) electrical system loads are not reduced. The front vehicle controller (VCFRONT) is shedding some vehicle electrical loads by cutting power to less essential electronic control units (ECUs).

Potential impact

Some convenience features will be unavailable as VCFRONT limits LV electrical system current draw by cutting power to some electronic control units (ECUs).

Set condition

The VCRIGHT eFuse current value equals or exceeds 100A for 100 milliseconds.

Clear condition

The VCRIGHT eFuse current value remains below 100A for 100 milliseconds.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ambient Temp VCFRONT_a509_ambientTemp degC
Vcright E Fuse Current VCFRONT_a509_vcrightEFuseCurrent A
Vcright E Fuse Temp VCFRONT_a509_vcrightEFuseTemp degC
Signal Unit
Frunk Open VCFRONT_a509_frunkOpen —
Service Mode VCFRONT_a509_serviceMode —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a509.