VCFRONT_a509 — Vcright eFuse Load Shed
Full alert identifier: VCFRONT_a509_vcrightEFuseLoadShed
Alert description
Electrical current flowing through the right vehicle controller (VCRIGHT) eFuse has equaled or exceeded 100A. The VCRIGHT eFuse circuit may open (trip) if low voltage (LV) electrical system loads are not reduced. The front vehicle controller (VCFRONT) is shedding some vehicle electrical loads by cutting power to less essential electronic control units (ECUs).
Potential impact
Some convenience features will be unavailable as VCFRONT limits LV electrical system current draw by cutting power to some electronic control units (ECUs).
Set condition
The VCRIGHT eFuse current value equals or exceeds 100A for 100 milliseconds.
Clear condition
The VCRIGHT eFuse current value remains below 100A for 100 milliseconds.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Ambient Temp
VCFRONT_
|
degC |
Vcright E Fuse Current
VCFRONT_
|
A |
Vcright E Fuse Temp
VCFRONT_
|
degC |
| Signal | Unit |
|---|---|
Frunk Open
VCFRONT_
|
— |
Service Mode
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a509.