VCFRONT_a146 — Pump Chiller Soft Stall

Full alert identifier: VCFRONT_a146_pumpChillerSoftStall

Alert description

The vehicle controller detects the chiller pump motor is unable to reach the target RPM, which may prevent the chiller pump from running as expected.

Potential impact

Powertrain performance may be limited.

Set condition

The chiller pump motor is unable to reach the target RPM.

Clear condition

The chiller pump resets or reaches the target RPM.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
RPM Actual VCFRONT_a146_RPMActual RPM
RPM Target VCFRONT_a146_RPMTarget RPM

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a146.