VCBATT_a479 — LVBMS ECPA Not Closed
Full alert identifier: VCBATT_a479_LVBMS_ECPA_NotClosed
Message shown in the car
Connector on low voltage battery is not secured Push or slide locking mechanism until secured
Alert description
The low voltage battery management system (LVBMS) is reporting the low voltage (LV) battery's electronic connector position assurance (E-CPA) is not secure, which could result in the LV battery becoming disconnected from the rest of the vehicle electrical systems. This could occur due to the E-CPA locking tab not being fully pushed down, or communication issues between the LVBMS and vehicle controller.
Potential impact
The LV battery may become (or may already be) disconnected from the rest of the vehicle electrical systems, which would make the LV battery unable to support vehicle electrical systems or to recharge via the power conversion system (PCS).
Set condition
The LVBMS is not communicating as expected with the vehicle controller (MIA) or reports the LV battery's E-CPA is not closed.
Clear condition
The LVBMS is communicating as expected with the vehicle controller (not MIA) and reports the LV battery's E-CPA is closed.
Signals to check
These diagnostic fields are associated with VCBATT_a479. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
ECPA State
VCBATT_
|
— |
FRM 3 Timed Out
VCBATT_
|
— |
Battery SM State
VCBATT_
|
— |
Factory Mode
VCBATT_
|
— |
Frunk Latch Status
VCBATT_
|
— |
Service Mode
VCBATT_
|
— |
Transport Mode
VCBATT_
|
— |
Vehicle Power State
VCBATT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a479.