Skip to content

VCBATT_a561 — LVBMS eFuse Overtemperature

Full alert identifier: VCBATT_a561_LVBMSEFuseOvertemperature

Alert description

The Low Voltage Battery Management System (LVBMS) detects high temperature at the low voltage (LV) battery MOSFET (internal protection transistor).

Potential impact

The low voltage (LV) battery may show degraded performance or become unavailable due to high temperatures.

Set condition

The LVBMS MOSFET temperature has reached 100 deg C for 1 second.

Clear condition

The LVBMS is no longer reporting high MOSFET temperature.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ambient Temperature VCBATT_a561_ambientTemperature C
Cell 1 Voltage VCBATT_a561_cell1Voltage V
Cell 2 Voltage VCBATT_a561_cell2Voltage V
Cell 3 Voltage VCBATT_a561_cell3Voltage V
Cell 4 Voltage VCBATT_a561_cell4Voltage V
Efuse Temperature VCBATT_a561_efuseTemperature C
Pack Temperature VCBATT_a561_packTemperature C
Signal Unit
Factory Mode VCBATT_a561_factoryMode —
Frunk Open VCBATT_a561_frunkOpen —
Service Mode VCBATT_a561_serviceMode —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a561.

Browse all VCBATT alert codes