Alert description

The low voltage battery management system (LVBMS) has opened the low voltage (LV) battery's internal protection transistor (MOSFET), disconnecting the LV battery from the rest of the vehicle electrical systems.

Potential impact

The LV battery is unable to support vehicle electrical systems or to recharge via the power conversion system (PCS). The high voltage (HV) system will remain energized to continue supplying electrical power to the vehicle while the LV battery is unavailable. This may result in greater range loss than expected, increased HV system energy consumption when the vehicle is idle, and prevent the vehicle from sleeping.

Set condition

The LVBMS reports the LV battery's internal protection transistor (MOSFET) is open.

Clear condition

The LVBMS reports the LV battery's internal protection transistor (MOSFET) is closed again.

Signals to check

These diagnostic fields are associated with VCBATT_a478. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bms mia VCBATT_a478_BMS_MIA —
HV Blocking Mismatch VCBATT_a478_HVBlockingMismatch —
Hv up VCBATT_a478_HV_UP —
Pcs mia VCBATT_a478_PCS_MIA —
Batt Fault Cell Over Voltage VCBATT_a478_battFaultCellOverVoltage —
Batt Fault Cell Under Voltage VCBATT_a478_battFaultCellUnderVoltage —
Batt Fault Charge Over Current VCBATT_a478_battFaultChargeOverCurrent —
Batt Fault Hardware Over Current VCBATT_a478_battFaultHardwareOverCurrent —
Show 15 more fields
Signal Unit
Batt Fault Pack Over Voltage VCBATT_a478_battFaultPackOverVoltage —
Battery SM State VCBATT_a478_batterySMState —
Bms State VCBATT_a478_bmsState —
Contactor E Fuse Stable VCBATT_a478_contactorEFuseStable —
Crash Detected VCBATT_a478_crashDetected —
Dcdc LV Support Status VCBATT_a478_dcdcLVSupportStatus
0
IDLE
1
ACTIVE
2
FAULTED
—
Factory Mode VCBATT_a478_factoryMode —
Frunk Open VCBATT_a478_frunkOpen —
Hvc E Fuse Stable VCBATT_a478_hvcEFuseStable —
Not Enough Power For Support VCBATT_a478_notEnoughPowerForSupport —
Pcs E Fuse Stable VCBATT_a478_pcsEFuseStable —
Service Mode VCBATT_a478_serviceMode —
Transport Mode VCBATT_a478_transportMode —
Vcright E Fuse Stable VCBATT_a478_vcrightEFuseStable —
Vehicle Power State VCBATT_a478_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—