Skip to content

PMF_a026 — Di Heart Beat MIA

Full alert identifier: PMF_a026_diHeartBeatMIA

Alert description

Pedal Monitor Warning: DI Heartbeat is missing.

Potential impact

The safety monitor will initiate a unit limp condition for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition when DI Heartbeat communication is too fast or too slow.

Clear condition

This alert will clear when DI Heartbeat communication are considered rational.

Signals to check

These diagnostic fields are associated with PMF_a026. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Control Stack Ovf PMF_a026_controlStackOvf —
Eep Stack Ovf PMF_a026_eepStackOvf —
Idle Stack Ovf PMF_a026_idleStackOvf —
Imm Stack Ovf PMF_a026_immStackOvf —
Isr Count 1 K Hz PMF_a026_isrCount1kHz —
Isr Count 20 K Hz PMF_a026_isrCount20kHz —
Reason PMF_a026_reason
0
TooSlow
1
TooFast
—
Switching Active PMF_a026_switchingActive —
Show 3 more fields
Signal Unit
System Stack Ovf PMF_a026_systemStackOvf —
Xdc Error Arg 1 PMF_a026_xdcErrorArg1 —
Xdc Error Id MSW PMF_a026_xdcErrorIdMSW —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMF_a026.