Skip to content

PCS_a011 — Chg Llc Current Regulation

Full alert identifier: PCS_a011_chgLlcCurrentRegulation

Alert description

Charger is not able to regulate its output current

Potential impact

Reduced AC charge rate or inability to AC charge

Set condition

Charger LLC current regulator error exceeds threshold

Clear condition

Charger LLC current regulator error is below clear threhsold

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Int Bus V PCS_a011_intBusV V
Llc Current PCS_a011_llcCurrent A
Llc Current Target PCS_a011_llcCurrentTarget A
Llc Frequency PCS_a011_llcFrequency kHz
Output V PCS_a011_outputV V
Signal Unit
Ph State PCS_a011_phState
0
INIT
1
IDLE
2
PRECHARGE
3
ENABLE
4
FAULT
5
CLEAR FAULTS
6
SHUTTING DOWN
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a011.

Browse all PCS alert codes