Skip to content

PCS_a009 — Chg Pfc Current Regulation

Full alert identifier: PCS_a009_chgPfcCurrentRegulation

Alert description

Charger is not able to regulate its input current

Potential impact

Reduced AC charge rate or inability to AC charge

Set condition

Charger PFC current regulator error exceeds threshold

Clear condition

Charger PFC current regulator error is below clear threshold

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Int Bus V PCS_a009_intBusV V
Llc Current PCS_a009_llcCurrent A
Pfc Current Rms PCS_a009_pfcCurrentRms A
Pfc Current Target PCS_a009_pfcCurrentTarget A
Signal Unit
Ph State PCS_a009_phState
0
INIT
1
IDLE
2
PRECHARGE
3
ENABLE
4
FAULT
5
CLEAR FAULTS
6
SHUTTING DOWN
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a009.

Browse all PCS alert codes