PCS_a008 — Chg Phase Over Temp
Full alert identifier: PCS_a008_chgPhaseOverTemp
Alert description
Charger detects phase termperature is too high to continue charging
Potential impact
Reduced AC charge rate or inability to AC charge
Set condition
Charger phase temperature exceeds overtemperature threshold for more than one second
Clear condition
Charger phase temperature is below overtemperature clear threshold for more than five seconds
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Input Irms
PCS_
|
A |
Input Vrms
PCS_
|
V |
Phase Temperature
PCS_
|
C |
| Signal | Unit |
|---|---|
Ph State
PCS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a008.