PCS_a008 — Chg Phase Over Temp

Full alert identifier: PCS_a008_chgPhaseOverTemp

Alert description

Charger detects phase termperature is too high to continue charging

Potential impact

Reduced AC charge rate or inability to AC charge

Set condition

Charger phase temperature exceeds overtemperature threshold for more than one second

Clear condition

Charger phase temperature is below overtemperature clear threshold for more than five seconds

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Input Irms PCS_a008_inputIrms A
Input Vrms PCS_a008_inputVrms V
Phase Temperature PCS_a008_phaseTemperature C
Signal Unit
Ph State PCS_a008_phState
0
INIT
1
IDLE
2
PRECHARGE
3
ENABLE
4
FAULT
5
CLEAR FAULTS
6
SHUTTING DOWN
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a008.

Browse all PCS alert codes