PCS_a080 — Damaged Phase Detected

Full alert identifier: PCS_a080_damagedPhaseDetected

Alert description

PCS has detected at least one damaged AC charging phase, AC charging power will be limited

Potential impact

Reduced AC charge rate or inability to AC charge

Set condition

Power conversion system detected reset while enabling a phase, and did not attempt to re-enable phase

Clear condition

Power conversion system is reset or power cycled

Signals to check

These diagnostic fields are associated with PCS_a080. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Ph A Damaged PCS_a080_phADamaged —
Ph ANVRAM Stored State PCS_a080_phANVRAMStoredState
0
PENDING
1
RUNNING CNT 0
2
RUNNING CNT 1
3
RUNNING CNT 2
4
RUNNING CNT EXPIRED
—
Ph B Damaged PCS_a080_phBDamaged —
Ph BNVRAM Stored State PCS_a080_phBNVRAMStoredState
0
PENDING
1
RUNNING CNT 0
2
RUNNING CNT 1
3
RUNNING CNT 2
4
RUNNING CNT EXPIRED
—
Ph C Damaged PCS_a080_phCDamaged —
Ph CNVRAM Stored State PCS_a080_phCNVRAMStoredState
0
PENDING
1
RUNNING CNT 0
2
RUNNING CNT 1
3
RUNNING CNT 2
4
RUNNING CNT EXPIRED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a080.

Browse all PCS alert codes