PCS_a080 — Damaged Phase Detected
Full alert identifier: PCS_a080_damagedPhaseDetected
Alert description
PCS has detected at least one damaged AC charging phase, AC charging power will be limited
Potential impact
Reduced AC charge rate or inability to AC charge
Set condition
Power conversion system detected reset while enabling a phase, and did not attempt to re-enable phase
Clear condition
Power conversion system is reset or power cycled
Signals to check
These diagnostic fields are associated with PCS_a080. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ph A Damaged
PCS_
|
— |
Ph ANVRAM Stored State
PCS_
|
— |
Ph B Damaged
PCS_
|
— |
Ph BNVRAM Stored State
PCS_
|
— |
Ph C Damaged
PCS_
|
— |
Ph CNVRAM Stored State
PCS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a080.