Skip to content

PCS_a097 — Reboot Phase Detected

Full alert identifier: PCS_a097_rebootPhaseDetected

Alert description

PCS has detected at least one reset during the boot up process. AC charging power might be limited if phase damaged is detected

Potential impact

Reduced AC charge rate or inability to AC charge if pahse damaged is detected

Set condition

Power conversion system detected reset while enabling a phase

Clear condition

Power conversion system is reset or power cycled

Signals to check

These diagnostic fields are associated with PCS_a097. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Ph A Damaged PCS_a097_phADamaged —
Ph ANVRAM Stored State PCS_a097_phANVRAMStoredState
0
PENDING
1
RUNNING CNT 0
2
RUNNING CNT 1
3
RUNNING CNT 2
4
RUNNING CNT EXPIRED
—
Ph B Damaged PCS_a097_phBDamaged —
Ph BNVRAM Stored State PCS_a097_phBNVRAMStoredState
0
PENDING
1
RUNNING CNT 0
2
RUNNING CNT 1
3
RUNNING CNT 2
4
RUNNING CNT EXPIRED
—
Ph C Damaged PCS_a097_phCDamaged —
Ph CNVRAM Stored State PCS_a097_phCNVRAMStoredState
0
PENDING
1
RUNNING CNT 0
2
RUNNING CNT 1
3
RUNNING CNT 2
4
RUNNING CNT EXPIRED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a097.

Browse all PCS alert codes