HVP_w018 — Power Cycling Pcs

Full alert identifier: HVP_w018_powerCyclingPcs

Alert description

The PCS is MIA and the HVP is power cycling it in an attempt to recover it

Potential impact

The PCS will be power cycled and temporarily no longer support the LV system

Set condition

The VC indicates that the conditions have been met to power cycle and the HVP has detected no CAN activity from the PCS

Clear condition

Either VC_goodForPCSPowerCycle is no longer asserted or the HVP detects PCS messages

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Battery 12 V HVP_a018_battery12V V
Dc Link Voltage HVP_a018_dcLinkVoltage V
Signal Unit
Gpio Chg Enable HVP_a018_gpioChgEnable —
Gpio Dc Dc Enable HVP_a018_gpioDcDcEnable —
Gpio Logic Power Enable HVP_a018_gpioLogicPowerEnable —
Hvc Hardware Supports Cycling HVP_a018_hvcHardwareSupportsCycling —
Pcs Hardware Ok To Be Power Cycled HVP_a018_pcsHardwareOkToBePowerCycled —
Remaining Pcs Power Cycles Allowed HVP_a018_remainingPcsPowerCyclesAllowed —
Remaining Pcs Recoveries Allowed HVP_a018_remainingPcsRecoveriesAllowed —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w018.

Browse all HVP alert codes