Skip to content

HVP_w006 — Over Charge Current Fault

Full alert identifier: HVP_w006_OverChargeCurrentFault

Alert description

Warns if the pack charge current is above max charge current limit

Potential impact

The DC charging will end and contactors may open immdediately or pyro may disconnect

Set condition

The pack charge current is above max charge current limit for X duration (in msec)

Clear condition

The pack charge current is below max charge current limit

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Current HVP_a006_current A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w006.

Browse all HVP alert codes