Skip to content

HVP_w008 — Over Temperature Fault

Full alert identifier: HVP_w008_OverTemperatureFault

Alert description

A pack module temperature is above maximum temperature limit

Potential impact

The conactors may open immdediately or pyro fuse may blow

Set condition

A pack module temperature is above maximum temperature limit for X duration (in seconds)

Clear condition

All pack module temperatures are below maximum temperature limit

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Temperature HVP_a008_temperature C
Signal Unit
Primary Chain Sensor HVP_a008_primaryChainSensor —
Sensor Id HVP_a008_sensorId —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w008.

Browse all HVP alert codes