Skip to content

DIREL_a103 — Low Flow

Full alert identifier: DIREL_a103_lowFlow

Message shown in the car

Rear left motor power may be limited OK to drive - Schedule service

Alert description

Drive Inverter Warning: Low flow rate of fluid

Potential impact

Drive unit enters unit limp mode (see DI_a126_limpMode)

Set condition

Insufficient cooling to the drive inverter is detected

Clear condition

Cooling is sufficient and a drive cycle is executed

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ambient Temp DIREL_a103_ambientTemp C
Fluid Tor Delta T DIREL_a103_fluidTorDeltaT C
Inverter Temp DIREL_a103_inverterTemp C
Rms Current DIREL_a103_rmsCurrent A
Sensor Temp Est DIREL_a103_sensorTempEst C
Signal Unit
Fluid Implausible DIREL_a103_fluidImplausible —
Low Flow Detected DIREL_a103_lowFlowDetected —
No Flow Detected DIREL_a103_noFlowDetected —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a103.

Browse all DIREL alert codes