Skip to content

DIREL_a076 — Lv Supply OV

Full alert identifier: DIREL_a076_lvSupplyOV

Alert description

The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a low voltage (LV) battery overvoltage event.

Potential impact

No immediate impact. Could damage drive inverter LV hardware if LV is continuously too high.

Set condition

LV supply voltage to DI exceeds the set upper voltage limit.

Clear condition

The LV supply drops below upper threshold.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Lv Supply V DIREL_a076_lvSupplyV V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a076.

Browse all DIREL alert codes