Skip to content

DIREL_a012 — Hvil Not Closed

Full alert identifier: DIREL_a012_hvilNotClosed

Alert description

Drive Inverter Warning: HVIL not CLOSED

Potential impact

Contactors may not close

Set condition

HVIL is no longer CLOSED

Clear condition

HVIL closing again

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Hvil Cm Voltage DIREL_a012_hvilCmVoltage V
Hvil Current DIREL_a012_hvilCurrent mA
Signal Unit
Active Dis On 3 V 3 DIREL_a012_activeDisOn3V3 —
Hvil Fault Gpio DIREL_a012_hvilFaultGpio —
Hvil Header Fault DIREL_a012_hvilHeaderFault —
Hvil Status DIREL_a012_hvilStatus
0
DISABLED
1
OPEN
2
CLOSED
3
SNA
—
Hvil Supply Pin DI DIREL_a012_hvilSupplyPinDI —
Hvil Supply Pin PM DIREL_a012_hvilSupplyPinPM —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a012.

Browse all DIREL alert codes