CC_a006 — Input Over Current
Full alert identifier: CC_a006_inputOverCurrent
Message shown in the car
Unable to charge - Wall Connector overcurrent Disconnect and retry or use different equipment
Alert description
Contactors opened due to measured current exceeding configured unit current limit or sharing network allocated current.
Potential impact
Wall connector will stop charging and retry at most 3 times before waiting for the cable to be cycled.
Set condition
Measured current exceeds configured limit or sharing network allocation by 10 percent + 1 A root mean square (RMS).
Clear condition
Contactors open for 10 seconds and less than 4 automatic retry attempts, or charge cable cycled.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Line 1 Current
CC_
|
A |
Line 2 Current
CC_
|
A |
Line 3 Current
CC_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a006.