Skip to content

CC_a006 — Input Over Current

Full alert identifier: CC_a006_inputOverCurrent

Message shown in the car

Unable to charge - Wall Connector overcurrent Disconnect and retry or use different equipment

Alert description

Contactors opened due to measured current exceeding configured unit current limit or sharing network allocated current.

Potential impact

Wall connector will stop charging and retry at most 3 times before waiting for the cable to be cycled.

Set condition

Measured current exceeds configured limit or sharing network allocation by 10 percent + 1 A root mean square (RMS).

Clear condition

Contactors open for 10 seconds and less than 4 automatic retry attempts, or charge cable cycled.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Line 1 Current CC_a006_line1Current A
Line 2 Current CC_a006_line2Current A
Line 3 Current CC_a006_line3Current A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a006.

Browse all CC alert codes