CC_a003 — CCID Tripped
Full alert identifier: CC_a003_CCIDTripped
Message shown in the car
Unable to charge - Wall Connector GFCI tripped Disconnect and retry or use different equipment
Alert description
Ground fault current exceeded threshold.
Potential impact
Wall connector will not allow charging until ground fault current path is corrected and the test rerun.
Set condition
Ground fault current exceeded threshold.
Clear condition
Ground fault current has been corrected, and the test rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Dc Gfci Current
CC_
|
A |
Gfci Rms Current
CC_
|
A |
Gfci Rms Current Avg
CC_
|
A |
| Signal | Unit |
|---|---|
Gfci Fault Bucket
CC_
|
— |
Gfci Fault Reason
CC_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a003.