CC_a004 — CCID Self Test Fault

Full alert identifier: CC_a004_CCIDSelfTestFault

Message shown in the car

Unable to charge - Wall Connector issue Wall Connector needs service

Alert description

Ground fault detection circuit self-test failed.

Potential impact

Wall connector will not allow charging until the ground fault circuit self-test passes.

Set condition

Ground fault detection circuit self-test failed.

Clear condition

Ground fault detection circuit self-test passed after being rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Gfci Self Test Current CC_a004_gfciSelfTestCurrent A
Gfci Self Test Duty CC_a004_gfciSelfTestDuty A
Signal Unit
Gfci Asic Error Bitfield CC_a004_gfciAsicErrorBitfield —
Gfci Error Reason CC_a004_gfciErrorReason
0
SNA
1
IO ERROR
2
ASIC REASON
3
DC OFFSET ERROR
4
AC OFFSET ERROR
5
TEST SIGNAL ERROR
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a004.