Skip to content

BMS_a181 — SW Shunt Over Temperature

Full alert identifier: BMS_a181_SW_Shunt_Over_Temperature

Alert description

This alert indicates that the shunt bar temperature is above what is nominally expected, which can be indicative of issues in the penthouse like 3rd party pyros or improperly installed HV components.

Potential impact

The output power during drive may be reduced. If a 3rd party pyro is installed or some component in the penthouse is improperly installed, devices in the HV chain may experience additional wear caused by experiencing higher temperatures.

Set condition

The shunt bar's temperature is above the set threshold during drive

Clear condition

The shunt bar's temperature is below the clear threshold while not in drive

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a181.