BMS_a022 — SW Over Current

Full alert identifier: BMS_a022_SW_Over_Current

Message shown in the car

Unable to drive PULL OVER SAFELY

Alert description

The Battery Management System (BMS) has detected a software overcurrent event.

Potential impact

Inability to charge, drive, or support the Low Voltage (LV) system

Set condition

The high voltage (HV) battery pack current (discharge or charge) exceeded the maximum limit.

Clear condition

The BMS detects that the condition clears.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Charge Accumulator Limit BMS_a022_chargeAccumulatorLimit A^2s
Charge Accumulator Value BMS_a022_chargeAccumulatorValue A^2s
Signal Unit
Charge Accumulator Violation BMS_a022_chargeAccumulatorViolation —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a022.