Skip to content

BMS_a097 — SW BMB Over CAN Communication

Full alert identifier: BMS_a097_SW_BMB_Over_CAN_Communication

Alert description

The Battery Management System (BMS) did not receive a synchronous set of battery monitoring board (BMB) data through the BMB-over-CAN interface.

Potential impact

The BMS performs BMB sensor data substitution to replace missing data from unreceived CAN frames.

Set condition

The BMS does not receive an expected CAN frame containing BMB information within the task timeout period.

Clear condition

All controller area network (CAN) frames containing BMB information are received at the expected task rate.

Signals to check

These diagnostic fields are associated with BMS_a097. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Missing Frame BMS_a097_missingFrame —
Timeout BMS_a097_timeout —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a097.

Browse all BMS alert codes