Skip to content

BMS_a099 — SW BMB Communication

Full alert identifier: BMS_a099_SW_BMB_Communication

Alert description

The Battery Management System (BMS) cannot communicate with all of the battery monitoring boards (BMBs).

Potential impact

This alert is primarily informational, and may indicate a loss of BMB sensor data

Set condition

A communication issue with the BMB daisy chain is detected.

Clear condition

No communication issues with the BMB daisy chain have been detected.

Signals to check

These diagnostic fields are associated with BMS_a099. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Alert From Hvp BMS_a099_alertFromHvp —
Bmb Chain Break Type BMS_a099_bmbChainBreakType
0
NONE
1
SINGLE BREAK
2
DOUBLE BREAK
3
INVALID BREAK
4
HEAD BREAK
5
TAIL BREAK
—
Bmb Comm Status Type A BMS_a099_bmbCommStatusTypeA
0
MISSING
1
BAD
2
NOMINAL
3
BYPASSED
—
Bmb Comm Status Type B BMS_a099_bmbCommStatusTypeB
0
MISSING
1
BAD
2
NOMINAL
3
BYPASSED
—
Break Location A BMS_a099_breakLocationA —
Break Location B BMS_a099_breakLocationB —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a099.