Skip to content

BMS_a049 — SW Thermal Event

Full alert identifier: BMS_a049_SW_Thermal_Event

Message shown in the car

Shutdown - Pull over and exit vehicle safely Immediate service is required

Alert description

The Battery Management System (BMS) detects conditions that indicate a potential propagating thermal event.

Potential impact

Indicates rapid temperature rise in conjunction with other critical alerts. Pack may remain inoperable and should be serviced according to proper procedures.

Set condition

At least one brick under/over voltage alert was recently active, and at least one isolation alert was recently active, and at least one battery monitoring board (BMB) missing (MIA) alert was recently active, and the max thermistor temp exceeds the limit, and the pack temperature gradient (maxTemp - minTemp) exceeds the threshold, and that gradient is increasing at a rate greater than the slop threshold.

Clear condition

None. This alert clears upon BMS reset.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a049.

Browse all BMS alert codes