Skip to content

BMS_a035 — SW Isolation

Full alert identifier: BMS_a035_SW_Isolation

Message shown in the car

Vehicle may not restart Service is required

Alert description

There is an external or internal isolation alert while pack contactors are closed.

Potential impact

Inability to charge, drive, or support the Low Voltage (LV) system

Set condition

The BMS detects that isolation is below the minimum threshold while contactors are closed.

Clear condition

Isolation restores to the nominal threshold.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Active Side V No R BMS_a035_activeSideVNoR V
Active Side V With R BMS_a035_activeSideVWithR V
Iso R BMS_a035_isoR kOhm
Passive Side V No R BMS_a035_passiveSideVNoR V
Passive Side V With R BMS_a035_passiveSideVWithR V
Signal Unit
Mode BMS_a035_mode
0
MODE RESET
1
VEHICLE ISOLATION MODE
2
FEIM NEGATIVE MODE
3
FEIM POSITIVE MODE
4
VOLTAGE SETTLING MODE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a035.

Browse all BMS alert codes