Skip to content

BMS_a142 — SW Isolation Degradation

Full alert identifier: BMS_a142_SW_Isolation_Degradation

Alert description

The Battery Management System (BMS) detects that the high voltage (HV) isolation contactor closed below the warning threshold.

Potential impact

This alert indicates that HV isolation is low, but above the sufficient level for vehicle operation.

Set condition

The BMS detects that the HV isolation was below the warning threshold when pack contactors closed.

Clear condition

The BMS detects that HV isolation is above the warning threshold when pack contactors closed.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Isolation Resistance BMS_a142_isolationResistance kOhm
Signal Unit
Mode BMS_a142_mode
0
MODE RESET
1
VEHICLE ISOLATION MODE
2
FEIM NEGATIVE MODE
3
FEIM POSITIVE MODE
4
VOLTAGE SETTLING MODE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a142.

Browse all BMS alert codes