BCFALCP_a144 — Upper Front Cur Limit
Full alert identifier: BCFALCP_a144_upperFrontCurLimit
Alert description
The Falcon Door Body Controller has detected the upper front actuator experienced a current limit surge lasting for over 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.
Potential impact
Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.
Set condition
The upper front actuator experienced a current limit surge lasting for over 100 milliseconds and exceeding 19A.
Clear condition
Upper rear actuator operates within normal current limits without experiencing any surges.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Current Limit
BCFALCP_
|
A |
Over Current Time Ms
BCFALCP_
|
INTEGRAL |
Upper Door Angle
BCFALCP_
|
deg |
Upper Front Max Curren
BCFALCP_
|
A |
Upper Rear Max Current
BCFALCP_
|
A |
| Signal | Unit |
|---|---|
Falcon State
BCFALCP_
|
— |
Is Calibrated
BCFALCP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCP_a144.