BCFALCP_a144 — Upper Front Cur Limit

Full alert identifier: BCFALCP_a144_upperFrontCurLimit

Alert description

The Falcon Door Body Controller has detected the upper front actuator experienced a current limit surge lasting for over 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.

Potential impact

Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.

Set condition

The upper front actuator experienced a current limit surge lasting for over 100 milliseconds and exceeding 19A.

Clear condition

Upper rear actuator operates within normal current limits without experiencing any surges.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Current Limit BCFALCP_a144_currentLimit A
Over Current Time Ms BCFALCP_a144_overCurrentTimeMs INTEGRAL
Upper Door Angle BCFALCP_a144_upperDoorAngle deg
Upper Front Max Curren BCFALCP_a144_upperFrontMaxCurren A
Upper Rear Max Current BCFALCP_a144_upperRearMaxCurrent A
Signal Unit
Falcon State BCFALCP_a144_falconState —
Is Calibrated BCFALCP_a144_isCalibrated —