BCFALCP_a147 — Lower Rear Cur Limit
Full alert identifier: BCFALCP_a147_lowerRearCurLimit
Alert description
The Falcon Door Body Controller has detected lower rear actuator current limit has been surpassed for more than 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.
Potential impact
Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.
Set condition
The lower rear actuator experienced a current limit surge lasting for over 100 milliseconds and exceeds 19A.
Clear condition
Lower rear actuator operates within normal current limits without experiencing any surges.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Current Limit
BCFALCP_
|
A |
Lower Door Angle
BCFALCP_
|
deg |
Lower Front Max Curren
BCFALCP_
|
A |
Lower Rear Max Current
BCFALCP_
|
A |
Over Current Time Ms
BCFALCP_
|
INTEGRAL |
| Signal | Unit |
|---|---|
Falcon State
BCFALCP_
|
— |
Is Calibrated
BCFALCP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCP_a147.