Skip to content
Model X

BCFALCP_a130 — Upper Front Cur Error

Full alert identifier: BCFALCP_a130_upperFrontCurError

Alert description

This alert is our best guess at which actuator is problematic, but this could be incorrect. Note: current in this measurement is absolute (sign doesn't matter).

Potential impact

Current differences could indicate damaged, miswired, or unplugged actuators

Set condition

Upper Front Current is 10 Amps lower than upper rear

Clear condition

A new actuation request comes in

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Upper Door Angle BCFALCP_a130_upperDoorAngle deg
Upper Front Current BCFALCP_a130_upperFrontCurrent A
Upper Rear Current BCFALCP_a130_upperRearCurrent A
Upper Speed Diff BCFALCP_a130_upperSpeedDiff deg/s
Signal Unit
Door Mvmt Direction BCFALCP_a130_doorMvmtDirection
0
OPENING
1
CLOSING
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCP_a130.

Browse all BCFALCP alert codes