VCFRONT1_a597 — Vcright Fast Blow Power Cutoff
Full alert identifier: VCFRONT1_a597_vcrightFastBlowPowerCutoff
Message shown in the car
Unable to drive - Service is required Electrical system issue detected
Alert description
The front vehicle controller (VCFRONT) detects a power draw higher than expected from the right vehicle controller (VCRIGHT), causing the VCFRONT to power off the VCRIGHT.
Potential impact
Vehicle may be unable to drive and may start to power down. Vehicle functions that depend on the VCRIGHT (such as right side windows, doors, and/or seat functions) may be unavailable or their performance may be affected.
Set condition
There is a sudden high power draw being observed on the VCRIGHT that is outside of the defined operating threshold.
Clear condition
The VCRIGHT is serviced, and the VCFRONT determines the VCRIGHT power cutoff is no longer required.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Vcright Cutoff Current Threshold
VCFRONT1_
|
A |
| Signal | Unit |
|---|---|
Vcright Cutoff E Fuse Fast Blow Type
VCFRONT1_
|
— |
Vcright Cutoff Max Count
VCFRONT1_
|
— |
Vcright Cutoff Timing Threshold Ms
VCFRONT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a597.