VCFRONT1_a128 — Vcright eFuse Trip
Full alert identifier: VCFRONT1_a128_vcrightEFuseTrip
Alert description
The front vehicle controller (VCFRONT) has opened the Low voltage (LV) power feed circuit (eFuse) to the right vehicle controller (VCRIGHT), interrupting power supply to VCRIGHT.
Potential impact
Functions on the right side of the vehicle may be limited or unavailable.
Set condition
VCFRONT detects the eFuse circuit gating LV power feed to VCRIGHT as open (tripped).
Clear condition
VCFRONT no longer detects the eFuse circuit gating LV power feed to VCRIGHT as open (tripped) after a retry or sleep cycle, or the vehicle enters a state where the eFuse is expected to be open (off).
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Vcright E Fuse Current
VCFRONT1_
|
A |
Vcright E Fuse Temp
VCFRONT1_
|
degC |
Vcright E Fuse Voltage
VCFRONT1_
|
V |
| Signal | Unit |
|---|---|
Vcright E Fuse Remaining Retries
VCFRONT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a128.