VCFRONT1_a216 — Power Cutoff Imminent
Full alert identifier: VCFRONT1_a216_powerCutoffImminent
Message shown in the car
Vehicle may not restart - Service is required Electrical system issue detected
Alert description
The front vehicle controller (VCFRONT) detects a power draw higher than expected from the left or right vehicle controller (VCLEFT / VCRIGHT) while in DRIVE or during a DC charging session.
Potential impact
Vehicle may be unable to drive and may start to power down after exiting DRIVE or after the DC charging session is complete.
Set condition
There is a sudden high power draw being observed on the VCLEFT or VCRIGHT that is outside of the defined operating threshold.
Clear condition
The VCFRONT determines the VCRIGHT or VCLEFT power cutoff is no longer required.
Signals to check
These diagnostic fields are associated with VCFRONT1_a216. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Hv State
VCFRONT1_
|
— |
In Drive
VCFRONT1_
|
— |
Vcright Dynamic Imminent
VCFRONT1_
|
— |
Vcright Fast Blow Debounce Imminent
VCFRONT1_
|
— |
Vcright Fast Blow Imminent
VCFRONT1_
|
— |
Vcright Static Imminent
VCFRONT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a216.