Skip to content

VCFRONT1_a252 — Pcs Ov Shutdown Self Test Stage Failure

Full alert identifier: VCFRONT1_a252_pcsOvShutdownSelfTestStageFailure

Alert description

One or more stages of the Power Conversion System (PCS) overvoltage shutdown self-test on the Front Vehicle Controller (VCFRONT) is unsuccessful.

Potential impact

The PCS overvoltage shutdown circuit may not be functional.

Set condition

One or more stages of the PCS overvoltage shutdown self-test is unsuccessful.

Clear condition

The VCFRONT resets, or the PCS overvoltage shutdown self-test is successful.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Bus Voltage VCFRONT1_a252_busVoltage V
Dcdc Enable Line Voltage VCFRONT1_a252_dcdcEnableLineVoltage V
Ov Clamp Monitor Voltage VCFRONT1_a252_ovClampMonitorVoltage V
Signal Unit
Incorrect Clamp Monitor 1 Voltage VCFRONT1_a252_incorrectClampMonitor1Voltage —
Incorrect Clamp Monitor 2 Voltage VCFRONT1_a252_incorrectClampMonitor2Voltage —
Incorrect Clamp Monitor 3 Voltage VCFRONT1_a252_incorrectClampMonitor3Voltage —
Incorrect Pcs Dcdc Enable Feedback VCFRONT1_a252_incorrectPcsDcdcEnableFeedback —
Incorrect Pcs Enable Line Voltage VCFRONT1_a252_incorrectPcsEnableLineVoltage —
Incorrect Pcs Support Status VCFRONT1_a252_incorrectPcsSupportStatus —
Incorrect Pcs Trip State VCFRONT1_a252_incorrectPcsTripState —
Incorrect Pin Configuration VCFRONT1_a252_incorrectPinConfiguration —
Show 8 more fields
Signal Unit
Ov Clamp Monitor Channel VCFRONT1_a252_ovClampMonitorChannel —
Pcs Dcdc Enable Feedback VCFRONT1_a252_pcsDcdcEnableFeedback —
Pcs Ov Clamp Armed VCFRONT1_a252_pcsOvClampArmed —
Pcs Ov Self Test Enabled VCFRONT1_a252_pcsOvSelfTestEnabled —
Pcs Ov Shutdown Armed VCFRONT1_a252_pcsOvShutdownArmed —
Pcs Ov Shutdown Fault Pin Active VCFRONT1_a252_pcsOvShutdownFaultPinActive —
Pcs Supporting VCFRONT1_a252_pcsSupporting —
Stage VCFRONT1_a252_stage
0
UNDEFINED
1
RATIONALITY SETUP CHECK
2
CLAMP LOW SIDE CHECK
3
RATIONALITY SHUTDOWN ARMED CHECK
4
CLAMP HIGH SIDE CHECK
5
RATIONALITY PCS SHUTDOWN CHECK
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a252.

Browse all VCFRONT1 alert codes