VCFRONT1_a252 — Pcs Ov Shutdown Self Test Stage Failure
Full alert identifier: VCFRONT1_a252_pcsOvShutdownSelfTestStageFailure
Alert description
One or more stages of the Power Conversion System (PCS) overvoltage shutdown self-test on the Front Vehicle Controller (VCFRONT) is unsuccessful.
Potential impact
The PCS overvoltage shutdown circuit may not be functional.
Set condition
One or more stages of the PCS overvoltage shutdown self-test is unsuccessful.
Clear condition
The VCFRONT resets, or the PCS overvoltage shutdown self-test is successful.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Bus Voltage
VCFRONT1_
|
V |
Dcdc Enable Line Voltage
VCFRONT1_
|
V |
Ov Clamp Monitor Voltage
VCFRONT1_
|
V |
| Signal | Unit |
|---|---|
Incorrect Clamp Monitor 1 Voltage
VCFRONT1_
|
— |
Incorrect Clamp Monitor 2 Voltage
VCFRONT1_
|
— |
Incorrect Clamp Monitor 3 Voltage
VCFRONT1_
|
— |
Incorrect Pcs Dcdc Enable Feedback
VCFRONT1_
|
— |
Incorrect Pcs Enable Line Voltage
VCFRONT1_
|
— |
Incorrect Pcs Support Status
VCFRONT1_
|
— |
Incorrect Pcs Trip State
VCFRONT1_
|
— |
Incorrect Pin Configuration
VCFRONT1_
|
— |
Show 8 more fields
| Signal | Unit |
|---|---|
Ov Clamp Monitor Channel
VCFRONT1_
|
— |
Pcs Dcdc Enable Feedback
VCFRONT1_
|
— |
Pcs Ov Clamp Armed
VCFRONT1_
|
— |
Pcs Ov Self Test Enabled
VCFRONT1_
|
— |
Pcs Ov Shutdown Armed
VCFRONT1_
|
— |
Pcs Ov Shutdown Fault Pin Active
VCFRONT1_
|
— |
Pcs Supporting
VCFRONT1_
|
— |
Stage
VCFRONT1_
|
— |
Check other alerts