Skip to content

VCFRONT1_a251 — Pcs Ov Shutdown Self Test Failure

Full alert identifier: VCFRONT1_a251_pcsOvShutdownSelfTestFailure

Alert description

The Power Conversion System (PCS) overvoltage shutdown self-test on the Front Vehicle Controller (VCFRONT) is unsuccessful.

Potential impact

The PCS overvoltage shutdown circuit may not be functional. Separate LVUnhealthy alert indicating a condition affecting low voltage (LV) electrical system will also be present.

Set condition

The PCS overvoltage shutdown self-test is unsuccessful. Alert log signal data provides information on the specific condition(s) detected.

Clear condition

The VCFRONT resets, or the PCS overvoltage shutdown self-test is successful.

Signals to check

These diagnostic fields are associated with VCFRONT1_a251. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Clamp High Side Check Result VCFRONT1_a251_clampHighSideCheckResult
0
INVALID
1
FAILED
2
PASSED
—
Clamp High Side Failure Reason VCFRONT1_a251_clampHighSideFailureReason
0
NONE
1
INCORRECT PIN CONFIGURATION
2
INCORRECT CLAMP MONITOR VOLTAGE
3
INCORRECT PCS ENABLE LINE VOLTAGE
4
INCORRECT PCS TRIP STATE
5
INCORRECT PCS SUPPORT STATUS
6
INCORRECT PCS DCDC ENABLE FEEDBACK
7
MULTIPLE
—
Clamp Low Side Check Result VCFRONT1_a251_clampLowSideCheckResult
0
INVALID
1
FAILED
2
PASSED
—
Clamp Low Side Failure Reason VCFRONT1_a251_clampLowSideFailureReason
0
NONE
1
INCORRECT PIN CONFIGURATION
2
INCORRECT CLAMP MONITOR VOLTAGE
3
INCORRECT PCS ENABLE LINE VOLTAGE
4
INCORRECT PCS TRIP STATE
5
INCORRECT PCS SUPPORT STATUS
6
INCORRECT PCS DCDC ENABLE FEEDBACK
7
MULTIPLE
—
Rationality Pcs Shutdown Check Result VCFRONT1_a251_rationalityPcsShutdownCheckResult
0
INVALID
1
FAILED
2
PASSED
—
Rationality Pcs Shutdown Failure Reason VCFRONT1_a251_rationalityPcsShutdownFailureReason
0
NONE
1
INCORRECT PIN CONFIGURATION
2
INCORRECT CLAMP MONITOR VOLTAGE
3
INCORRECT PCS ENABLE LINE VOLTAGE
4
INCORRECT PCS TRIP STATE
5
INCORRECT PCS SUPPORT STATUS
6
INCORRECT PCS DCDC ENABLE FEEDBACK
7
MULTIPLE
—
Rationality Setup Check Result VCFRONT1_a251_rationalitySetupCheckResult
0
INVALID
1
FAILED
2
PASSED
—
Rationality Setup Failure Reason VCFRONT1_a251_rationalitySetupFailureReason
0
NONE
1
INCORRECT PIN CONFIGURATION
2
INCORRECT CLAMP MONITOR VOLTAGE
3
INCORRECT PCS ENABLE LINE VOLTAGE
4
INCORRECT PCS TRIP STATE
5
INCORRECT PCS SUPPORT STATUS
6
INCORRECT PCS DCDC ENABLE FEEDBACK
7
MULTIPLE
—
Show 3 more fields
Signal Unit
Rationality Shutdown Armed Check Result VCFRONT1_a251_rationalityShutdownArmedCheckResult
0
INVALID
1
FAILED
2
PASSED
—
Rationality Shutdown Armed Failure Reason VCFRONT1_a251_rationalityShutdownArmedFailureReason
0
NONE
1
INCORRECT PIN CONFIGURATION
2
INCORRECT CLAMP MONITOR VOLTAGE
3
INCORRECT PCS ENABLE LINE VOLTAGE
4
INCORRECT PCS TRIP STATE
5
INCORRECT PCS SUPPORT STATUS
6
INCORRECT PCS DCDC ENABLE FEEDBACK
7
MULTIPLE
—
Test Timed Out VCFRONT1_a251_testTimedOut —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a251.

Browse all VCFRONT1 alert codes