VCFRONT1_a251 — Pcs Ov Shutdown Self Test Failure
Full alert identifier: VCFRONT1_a251_pcsOvShutdownSelfTestFailure
Alert description
The Power Conversion System (PCS) overvoltage shutdown self-test on the Front Vehicle Controller (VCFRONT) is unsuccessful.
Potential impact
The PCS overvoltage shutdown circuit may not be functional. Separate LVUnhealthy alert indicating a condition affecting low voltage (LV) electrical system will also be present.
Set condition
The PCS overvoltage shutdown self-test is unsuccessful. Alert log signal data provides information on the specific condition(s) detected.
Clear condition
The VCFRONT resets, or the PCS overvoltage shutdown self-test is successful.
Signals to check
These diagnostic fields are associated with VCFRONT1_a251. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Clamp High Side Check Result
VCFRONT1_
|
— |
Clamp High Side Failure Reason
VCFRONT1_
|
— |
Clamp Low Side Check Result
VCFRONT1_
|
— |
Clamp Low Side Failure Reason
VCFRONT1_
|
— |
Rationality Pcs Shutdown Check Result
VCFRONT1_
|
— |
Rationality Pcs Shutdown Failure Reason
VCFRONT1_
|
— |
Rationality Setup Check Result
VCFRONT1_
|
— |
Rationality Setup Failure Reason
VCFRONT1_
|
— |
Show 3 more fields
| Signal | Unit |
|---|---|
Rationality Shutdown Armed Check Result
VCFRONT1_
|
— |
Rationality Shutdown Armed Failure Reason
VCFRONT1_
|
— |
Test Timed Out
VCFRONT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a251.