Skip to content

VCFRONT1_a414 — Undervoltage Self Test Failure

Full alert identifier: VCFRONT1_a414_undervoltageSelfTestFailure

Alert description

The PCS Domain Undervoltage self-test did not pass. A condition affecting a load on the PCS Domain was detected during the self-test.

Potential impact

The undervoltage protection circuit may not function as expected.

Set condition

The PCS Domain Undervoltage self-test does not pass. If a stuck-on or stuck-off condition is present, specific information can be found in the undervoltage self-test stuck-on or stuck-off debugging alerts.

Clear condition

Vehicle controller resets or successful PCS Domain Undervoltage self-test.

Signals to check

These diagnostic fields are associated with VCFRONT1_a414. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bridge Failed To Open VCFRONT1_a414_bridgeFailedToOpen —
Device Stuck On Failure VCFRONT1_a414_deviceStuckOnFailure —
Failure Reason VCFRONT1_a414_failureReason
0
NONE
1
DEVICE STUCK ON
2
BRIDGE
3
BRIDGE AND DEVICE STUCK ON
4
LOAD UNATTEMPTED ON
8
FOLLOWER
16
TIMEOUT
32
BRIDGE SYNC
—
Follower VC Right Self Test Failure VCFRONT1_a414_followerVCRightSelfTestFailure —
Load Unattempted On Failure VCFRONT1_a414_loadUnattemptedOnFailure —
Uv Loadshed Vsense Dig In VCFRONT1_a414_uvLoadshedVsenseDigIn —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a414.

Browse all VCFRONT1 alert codes