VCFRONT1_a250 — Pcs Ov Shutdown Tripped
Full alert identifier: VCFRONT1_a250_pcsOvShutdownTripped
Alert description
The Power Conversion System (PCS) overvoltage shutdown protection is initiated on the Front Vehicle Controller (VCFRONT). The PCS support will be in IDLE until the protection clears.
Potential impact
The PCS DCDC is shut down and unavailable. Separate LVUnhealthy alert indicating a condition affecting low voltage (LV) electrical system will also be present.
Set condition
The 16V bus reports an overvoltage condition on VCFRONT while the vehicle is in Drive.
Clear condition
The vehicle is parked and the 16V bus voltage is below 18V, causing the PCS overvoltage shutdown protection to reset.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Bus Voltage
VCFRONT1_
|
V |
Dcdc Enable Line Voltage
VCFRONT1_
|
V |
Ov Clamp Bus Voltage
VCFRONT1_
|
V |
Ov Clamp Monitor Voltage 1
VCFRONT1_
|
V |
Ov Clamp Reference Voltage
VCFRONT1_
|
V |
| Signal | Unit |
|---|---|
Batt Domain Healthy
VCFRONT1_
|
— |
Pcs Ov Shutdown Armed
VCFRONT1_
|
— |
Pcs Ov Shutdown Fault Pin Active
VCFRONT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a250.