Skip to content

VCBATT1_a490 — Vnf1248 Self Test Failure

Full alert identifier: VCBATT1_a490_vnf1248SelfTestFailure

Alert description

VNF1248 self-test failed

Potential impact

EFuse hardware protections may not function

Set condition

EFuse self-test has failed

Clear condition

Controller reset or sleep cycle

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
VDS Diff VCBATT1_a490_VDSDiff mV
Current Sense Voltage Diff VCBATT1_a490_currentSenseVoltageDiff mV
Stuck On VDS VCBATT1_a490_stuckOnVDS mV
Signal Unit
VDS Failure VCBATT1_a490_VDSFailure —
VDS Finished VCBATT1_a490_VDSFinished —
Channel VCBATT1_a490_channel —
Current Sense Failure VCBATT1_a490_currentSenseFailure —
Current Sense Finished VCBATT1_a490_currentSenseFinished —
Hard Short Threshold Reached VCBATT1_a490_hardShortThresholdReached —
Output On VCBATT1_a490_outputOn —
Soft Short Threshold Reached VCBATT1_a490_softShortThresholdReached —
Show 3 more fields
Signal Unit
Stuck On Failure VCBATT1_a490_stuckOnFailure —
Stuck On Finished VCBATT1_a490_stuckOnFinished —
Timeout VCBATT1_a490_timeout —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a490.

Browse all VCBATT1 alert codes