VCBATT1_a223 — Bridge Overvoltage Self Test Failure

Full alert identifier: VCBATT1_a223_bridgeOvervoltageSelfTestFailure

Alert description

The bridge overvoltage self-test on the Battery Vehicle Controller (VCBATT) is unsuccessful.

Potential impact

The bridge overvoltage circuit may not be functional. An alert indicating the LV system is unhealthy (LVUnhealthy) sets. Explore the LVUnhealthy alert for more information on system limitations.

Set condition

The bridge overvoltage shutdown self-test is unsuccessful. Alert log signal data provides information on the specific condition(s) detected.

Clear condition

The VCBATT resets, or the bridge overvoltage self-test is successful.

Signals to check

These diagnostic fields are associated with VCBATT1_a223. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Failed Arming Setup VCBATT1_a223_failedArmingSetup —
Failed Fault Inject VCBATT1_a223_failedFaultInject —
Overvoltage Fault Active VCBATT1_a223_overvoltageFaultActive —
Shared Bridge Shutdown Active VCBATT1_a223_sharedBridgeShutdownActive —
Timed Out VCBATT1_a223_timedOut —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a223.

Browse all VCBATT1 alert codes