VCBATT1_a414 — Undervoltage Self Test Failure
Full alert identifier: VCBATT1_a414_undervoltageSelfTestFailure
Alert description
The Battery Domain Undervoltage self-test did not pass. A condition affecting a load on the Battery Domain was detected during the self-test.
Potential impact
The undervoltage protection circuit may not function as expected.
Set condition
The Battery Domain Undervoltage self-test does not pass. If a stuck-on or stuck-off condition is present, specific information can be found in the undervoltage self-test stuck-on or stuck-off debugging alerts.
Clear condition
Vehicle controller resets or successful Battery Domain Undervoltage self-test.
Signals to check
These diagnostic fields are associated with VCBATT1_a414. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bridge Failed To Open
VCBATT1_
|
— |
Device Stuck On Failure
VCBATT1_
|
— |
Failure Reason
VCBATT1_
|
— |
Follower VC Left Self Test Failure
VCBATT1_
|
— |
Load Unattempted On Failure
VCBATT1_
|
— |
Uv Loadshed Vsense Dig In
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a414.