VCBATT1_a371 — Failure To Precharge Risk
Full alert identifier: VCBATT1_a371_failureToPrechargeRisk
Alert description
Based on historical data, the vehicle controller determines there is a high probability the low voltage (LV) battery will not successfully precharge the high voltage (HV) bus.
Potential impact
The high voltage electrical system will remain on to support vehicle functions including drive (HV contactors will remain closed), causing the vehicle show greater range loss over time than expected.
Set condition
Any of the following alerts: 4 instances of LVVoltageDropOnHighLoadCurrent; one instance of shortedCell; one instance of deadLVMinimalAhDischarged; one instance of resistanceEstimationHardFailure; one instance of dcrMilliOhmsAboveThreshold; one instance of prechargeLVLoadReduction.
Clear condition
LV battery replacement should clear this alert.
Signals to check
These diagnostic fields are associated with VCBATT1_a371. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Dcr Milli Ohms Above Threshold Trigger
VCBATT1_
|
— |
Dead LV Minimal Ah Discharged Trigger
VCBATT1_
|
— |
Instant Precharge DCR Too High Trigger
VCBATT1_
|
— |
Precharge LV Load Reduction Trigger
VCBATT1_
|
— |
Resistance Estimation Hard Fail Trigger
VCBATT1_
|
— |
Shorted Cell Test Trigger
VCBATT1_
|
— |
Volt Drop On High Current Trigger
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a371.