VCBATT1_a235 — Dual Power Loads Self Test Failure
Full alert identifier: VCBATT1_a235_dualPowerLoadsSelfTestFailure
Alert description
The dual powered loads self-test on the Battery Vehicle Controller (VCBATT) did not complete successfully.
Potential impact
A redundant power circuit may not be operating as expected. An alert indicating the Low Voltage (LV) system is unhealthy and the (LVUnhealthy) alert sets. Explore the LVUnhealthy alert for more information on system limitations.
Set condition
The dual powered loads self-test did not complete successfully. Alert log signal data provides information on the specific condition(s) detected.
Clear condition
The VCBATT resets, or the dual powered loads self-test is successful.
Signals to check
These diagnostic fields are associated with VCBATT1_a235. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Hvc Left Domain Failure Reason
VCBATT1_
|
— |
Hvc Right Domain Failure Reason
VCBATT1_
|
— |
Timed Out
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a235.