VCBATT1_a217 — LV Protection Self Test Invalid
Full alert identifier: VCBATT1_a217_LVProtectionSelfTestInvalid
Alert description
A low voltage (LV) protection self-test result is invalid.
Potential impact
The LV protection circuits may not function as expected.
Set condition
Any LV protection self-test result is invalidated.
Clear condition
The self-test orchestrator runs and all test results are updated.
Signals to check
These diagnostic fields are associated with VCBATT1_a217. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
VC Batt Bridge Efuse Asic Result
VCBATT1_
|
— |
VC Front Bridge Efuse Asic Result
VCBATT1_
|
— |
Batt Domain Overcurrent Result
VCBATT1_
|
— |
Batt Domain Overvoltage Result
VCBATT1_
|
— |
Batt Domain Undervoltage Result
VCBATT1_
|
— |
Batt Domain Undervoltage VC Left Result
VCBATT1_
|
— |
Dual Power Loads Result
VCBATT1_
|
— |
Pcs Domain Overvoltage Result
VCBATT1_
|
— |
Show 5 more fields
| Signal | Unit |
|---|---|
Pcs Domain Undervoltage Result
VCBATT1_
|
— |
Pcs Domain Undervoltage VC Right Result
VCBATT1_
|
— |
Pcs Ov Shutdown Result
VCBATT1_
|
— |
Running Mode
VCBATT1_
|
— |
Start Reason
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a217.