Skip to content

PCS2_a103 — Iso Temp Sensor Irrational

Full alert identifier: PCS2_a103_IsoTempSensorIrrational

Alert description

An isolated temperature sensor measurement becomes irrational

Potential impact

DCDC and AC Charging may be limited or unavailable.

Set condition

An isolated temperature sensor measurement timing is beyond rational limits

Clear condition

An isolated temperature sensor measurement timing falls back within rational limits

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Closed Loop Time PCS2_a103_ClosedLoopTime nS
Fall Time Open Loop PCS2_a103_FallTimeOpenLoop nS
Rise Time Open Loop PCS2_a103_RiseTimeOpenLoop nS
Signal Unit
Iso Temp Sense Irrational PCS2_a103_IsoTempSenseIrrational —
Iso Temp Sense Out Of Bounds PCS2_a103_IsoTempSenseOutOfBounds —
Iso Temp Sensor PCS2_a103_IsoTempSensor —
Iso Temp Sensor Fall Time Out Of Bounds PCS2_a103_IsoTempSensorFallTimeOutOfBounds —
Iso Temp Sensor MIA PCS2_a103_IsoTempSensorMIA —
Iso Temp Sensor Rise Fall Mismatch PCS2_a103_IsoTempSensorRiseFallMismatch —
Iso Temp Sensor Rise Time Out Of Bounds PCS2_a103_IsoTempSensorRiseTimeOutOfBounds —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a103.

Browse all PCS2 alert codes