PCS2_a103 — Iso Temp Sensor Irrational
Full alert identifier: PCS2_a103_IsoTempSensorIrrational
Alert description
An isolated temperature sensor measurement becomes irrational
Potential impact
DCDC and AC Charging may be limited or unavailable.
Set condition
An isolated temperature sensor measurement timing is beyond rational limits
Clear condition
An isolated temperature sensor measurement timing falls back within rational limits
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Closed Loop Time
PCS2_
|
nS |
Fall Time Open Loop
PCS2_
|
nS |
Rise Time Open Loop
PCS2_
|
nS |
| Signal | Unit |
|---|---|
Iso Temp Sense Irrational
PCS2_
|
— |
Iso Temp Sense Out Of Bounds
PCS2_
|
— |
Iso Temp Sensor
PCS2_
|
— |
Iso Temp Sensor Fall Time Out Of Bounds
PCS2_
|
— |
Iso Temp Sensor MIA
PCS2_
|
— |
Iso Temp Sensor Rise Fall Mismatch
PCS2_
|
— |
Iso Temp Sensor Rise Time Out Of Bounds
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a103.