EPASTS_a130 — Mrcc Config Cs Error Err
Full alert identifier: EPASTS_a130_mrccConfigCsErrorErr
Alert description
This alert is reported when there is a CRC failure in the periodic register CRC checking. MCU internal error OR SW systematic failure
Potential impact
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
Set condition
EPAS MCU periodic register checking failure (CRC doesn't match the expected).
Clear condition
Perform EPAS Software update.
Signals to check
These diagnostic fields are associated with EPASTS_a130. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a130.