EPASTS_a116 — Mrcc Startup Reg Cs Error Static Err
Full alert identifier: EPASTS_a116_mrccStartupRegCsErrorStaticErr
Alert description
This alert is reported when the Start-up register check failed: MCU internal error OR SW systematic failure
Potential impact
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
Set condition
EPAS microcontroller's different registers does not contain the right values before starting the safety functions (CRC doesn't match for the second test fail).
Clear condition
Perform EPAS Software update. Replace HW if the alert persists.
Signals to check
These diagnostic fields are associated with EPASTS_a116. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a116.