EPASTS_a026 — Mrcc Cs Error Check Fail
Full alert identifier: EPASTS_a026_mrccCsErrorCheckFail
Alert description
This alert is reported when CRC check failed, consistency of non-inited memory sections did not keep during the restart.
Potential impact
EPAS full loss of assist.
Set condition
EPAS uC peripheral (SMU) alive test failure (CRC) at startup.
Clear condition
Perform EPAS Software update.
Signals to check
These diagnostic fields are associated with EPASTS_a026. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a026.