EPASTS_a018 — Exch Cs Error Check

Full alert identifier: EPASTS_a018_exchCsErrorCheck

Alert description

This alert is reported by the ExceptionHandler_TC3x (EXCH) component when the CRC mismatch is detected in the non-initialized data

Potential impact

EPAS full loss of assist.

Set condition

EPAS application component ExceptionHandler detected memory failure (CRC) at startup.

Clear condition

Perform EPAS Software update. If error persists, replace HW.