Skip to content
Model Y

EPASTS_a064 — Am Bridge Short

Full alert identifier: EPASTS_a064_amBridgeShort

Alert description

This alert is reported by the ActuatorManager_R12 (AM) component when the bridge FET test failed.

Potential impact

EPAS full loss of assist.

Set condition

EPAS ECU actuator monitor detected failure (bridge-FETs).

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a064. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a064_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a064.

Browse all EPASTS alert codes