Skip to content
Model Y

EPASTS_a141 — Am Fet Short Test

Full alert identifier: EPASTS_a141_amFetShortTest

Alert description

This alert is reported when Bridge FET short may be present.

Potential impact

EPAS full loss of assist.

Set condition

EPAS application diagnostics detected bridge fet short.

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a141. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a141_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a141.

Browse all EPASTS alert codes